4
5
6
3
2
F
45
17
E
Number of contacts
Contact arrangement
Contact arrangement
Rated voltage2)
Rated voltage
Rated impulse
withstand voltage2)
Pollution degree2)
Installation category
Insulation group
C
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung
und Mitteilung ihres Inhalts nicht gestattet, soweit nicht
ausdrücklich zugestanden. Zuwiderhandlungen verpflichten
zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung
oder Gebrauchsmuster-Eintragung vorbehalten.
Current rating
Insulation resistance
Contact resistance
Climatic category
Temperatur range
IP degree
Insertion and
withdrawal force
mechanical operation
housing material
dielectric material
contacts
termination technique
wire gauge
flamability
locking system
B
Standard
IEC 61076-2-106
1)
IEC
60130-9
IEC
60664-1
IEC
60664-1
60664-1
IEC 60664-1
IEC 60664-1
IEC 60512-5-2
UL 1977
IEC 60512-3-1
IEC 60512-2-1
IEC 60668-1
IEC 60668-1
ÎEC 60529
1200 V
(800 V)
IEC
IEC
60512-13-2
60512-9-1
Ag
T 3671 001 U
(14-b)
Au
T 3671 018 U
14
Ag
T 3651 001 U
(14-a)
Au
T 3651 000 U
12
Ag
T 3636 001 U
(12-a)
Au
T 3636 000 U
8
Ag
T 3505 001 U
(08-a)
Au
T 3505 018 U
7
(07-b)
Ag
T 3485 001 U
Au
T 3485 018 U
7
Ag
T 3476 001 U
(07-a)
Au
T 3476 018 U
14-b
19-a
(6-a)
Au
T 3401 018 U
5
Ag
T 3361 010 U
(05-b)
Au
T 3357 018 U
5
Ag
T 3361 001 U
(05-a)
Au
T 3361 018 U
4
(04-a)
Ag
T 3301 001 U
Au
T 3301 018 U
10 Ohm
-40°C...+100°C / -40°F...+212°F
IP 40
25N
30N
35N
35N
50N
55N
55N
60N
50N
50N
50N
60N
Silver >500 mating cycles / Gold >1000 mating cycles
UL 94 VO
metal screw coupling; tightening torque 0,7 - 1,5 Nm
Contact
Number of contacts
arrangement (Contact arrangement
acc.
View on
DIN EN 61076-2-106)
mating side
Gewicht (errechnet) / Calc WT : 29,13 g
Prüfmaß / Testdimension
Teileindex / Partindexnumber:
Edition 2000-05
values in brackets are according to DIN EN 61076-2-106
3)
under operating conditions >108 Ohm
A Do not connect or disconnect under load. Metal housing parts shall be securely incoporated to protected ground.
Remark for gold plated contacts:
In order to avoid brittle inter-metallic connections, gold plated terminals have to be tin-plated in the solder area.
All technical data have been measured in a laboratory environment and can be different during pratical usage of the product. Any product
information is for descriptive usage only and not legally binding; particulary the information does not constitute or provide any legal guaranties
("Beschaffenheitsgarantie" or " Haltbarkeitsgarantie").
5
Zul. Abw./Tolerances :
ISO
2768-c
Bagatelle change: 23.02.2021 MCARLE
Gez.
Maßstab / Scale : 2:1
E
D
C
202000083
Index Änderung/Description
01
05.02.2021 MCARL
Datum/Date Name
B
A3
CUSTOMER DRAWING
DIN / ISO
13715
08.12.2020
Drawn MCARLE
Status Released
Gepr. 10.02.2021
Checked MBERTSCH
2)
6
F
3)
brass and / or zinc die cast, nickel plated or thermoplast
thermoplastic
silver or gold plated
solder